B, lamps after impact test, leakage can not occur, not lighting and other electrical anomalies.
LED Downlight Third, the impact test temperature and pressure:
For objects: LED lamps (lamps with LEDDriver finished)
Reference standard: Industry Experience
Test method:
1, 5 LED lamps shall be placed in a room temperature of 25 ℃ environment;
2, according to the rated input voltage LED lamps powered lighting;
3, through the relay control lamp at room temperature and atmospheric pressure impact test, the test set to: lighting 30s, lights 30s, circulation 10,000 times.
Test requirements:
A, lamps after the impact test temperature and pressure, leakage can not occur, not lighting and other electrical anomalies.
Fourth, the temperature cycle test: GU10
For objects: LED lamps (lamps with LEDDriver finished)
Reference standard: Industry Experience
Test method:
1, 5 models LED lamps placed in a test chamber, temperature test chamber can be adjusted rate of temperature change;
2, according to the rated input voltage LED lamps powered lighting;
The list of tags is empty.